1. Use the 19 sequence hashboard tester SD card reflash application for The very first time to update the hashboard tester Management board FPGA, unzip it and copy it on the SD card, and afterwards insert the cardboard in the hashboard tester card slot; electricity on for approximately one minute and watch for the Management board indicator to double flash three situations, then the update is accomplished; (if It's not up-to-date, it may well bring about a specific chip to report fault in the check)
Irregular temperature: Usually, the temperature is higher. The utmost PCB temperature established by our monitoring program can not exceed 90℃.
Get the most effective mining general performance out within your Antminer S19 by using the ideal program. Be a part of minerstat and discover the most suitable software package in your setup.
six. The repaired hash board should be examined using a exam fixture, and it should pass a lot more than two situations to become judged as a superb solution. For The very first time, just after replacing the equipment, anticipate the hash board to chill down, utilize the take a look at fixture to test, and when is passed, put it on just one aspect right before cooling down. The second time, wait for the hash board to cool down entirely before testing.
In the event the chip’s look just isn't harmed, the chip with the lowest response level in each area should really get replaced.
five. When repairing and replacing the chip, you must check the chip very first, and afterwards do the functional test following passing. The functional take a look at ought to make sure the water-cooling plate is assembled correctly.
minerstat isn't just One more calculator - It can be a strong mining platform that supports your copyright journey. Improve your income, preserve worthwhile time, and maximize performance with our suite of top quality features:
Most likely, the IP can not be observed because of abnormal Procedure. Confer with the very first stage for troubleshooting.
Does any details on this page appears to be incorrect and you want Go Here to for us to examine it? Clarify The problem with just as much data as you can.
The admirer will alarm and it will not get the job done normally. Typically, the ambient temperature is just too substantial, plus the abnormal operation in the admirer can even bring about irregular temperature.
In case the miner of which the Command board has actually been reflashed has to start out Ordinarily, the next two techniques are essential:
3. When sensor NG is displayed around the Liquid crystal display monitor of your fixture, the exam examining temperature is irregular. Remember to Keep to the techniques under to troubleshoot:
Repair strategy: Examine the looks, measure the chip capacitor or resistor in entrance, it is often attributable to very poor soldering from the chip or a harmed chip capacitor or resistor or abnormal resistance worth;
a) LCD Screen ASICNG: if (0), 1st evaluate the overall voltage of your measuring area plus the Raise circuit 19V is usual, and then utilize the small-circuit probe to limited-circuit the RO examination level as well as the 1V8 check stage in between the first and the 2nd chip, then operate This system to find the chip.
Comments on “5 Tips about antminer s19 hashboard repair You Can Use Today”